CLI Quick Setup Script
4-7
Sample Output Display as Quick Setup Executes
OCR-DSL> set system name "name"
OCR-DSL>set system location "vienna"
OCR-DSL>set system contact "jc"
OCR-DSL>enable command password “password”
OCR-DSL>add snmp community public address 0.0.0.0 access RW
OCR-DSL>enable security_option remote_user administration
OCR-DSL>add user "root" password "!root"
OCR-DSL>add ip network “test” interface eth:1 address 192.168.200.254/C 
frame ethernet_ii enable no
OCR-DSL>set dhcp mode server
OCR-DSL>set dhcp server start 192.168.200.1 end 192.168.200.40 router 
192.168.200.254 dnsl 192.168.200.254 dns2 0.0.0.0 wins1 0.0.0. wins2 0.0.0.0 
mask 255.255.255.0
OCR-DSL>add dns host ocrdsl-3com.com addr 192.168.200.254
OCR-DSL>enable dns
OCR-DSL>add tftp client 0.0.0.0
OCR-DSL>set ip network “test” routing ripv2
OCR-DSL>enable ip network “test”
OCR-DSL>enable ip forwarding
OCR-DSL>add ipx network “ipx” address 12345661 interface eth:1 frame 
“ethernet_ii”
OCR-DSL>disable bridge spanning_tree
OCR-DSL>add bridge network “bridge”
OCR-DSL>save all
Saving..... SAVE ALL 
SAVE ALL  Complete
OCR-DSL>Spawned Process CFP 282002 /./QuickSetup.commands Completed 
Successfully
Quick Setup (CLI) is designed only for initial set up of the OCR 812. When setup is 
complete, this one-time program will alter your configuration files (which the 
program cannot edit). If you make an error and need to restart, use the delete 
configuration
 command to reboot and return to factory default settings.