3com 5500-ei pwr Guía De Instalación Rápida

Descargar
Página de 118
108
A
PPENDIX
 C: T
ECHNICAL
 S
PECIFICATIONS
RPS
Standards Supported
SNMP
SNMP protocol (RFC 1157)
MIB-II (RFC 1213)
Bridge MIB (RFC 1493)
RMON MIB II (RFC 2021)
Remote Monitoring MIB (RFC 
1757)
MAU MIB (RFC 2239)
MIB II Traps (RFC 1215)
RS232 (RFC 1659)
Interfaces (RFC 2233)
Ether-like MIB (RFC 2665)
MAU MIB (RFC 2668)
Bridge extensions (RFC 2674)
Terminal Emulation
Telnet (RFC 854)
Protocols Used for Administration
UDP (RFC 768)
IP (RFC 791)
ICMP (RFC 792)
TCP (RFC 793)
ARP (RFC 826)
TFTP (RFC 783)
DHCP (RFC 2131, RFC 2132, RFC 1534)
BOOTP (RFC 951, RFC 1497)
Network Login (IEEE 802.1x) 
RADIUS (RFC 2618, 2620)
Link aggregation (IEEE 802.3ad)
Safety Requirements
The RPS shall comply with the following safety standards:
EN60950, UL60950, CSA22.2 60950, IEC60950
When the output is floating (not referenced to earth), the RPS shall meet the 
requirements for a Safety Extra Low Voltage (SELV) circuit as defined by these 
standards
EMC
Emissions
CISPR 22 Class A, EN55022 Class A, FCC Part 15 Subpart B Class A, 
ICES-003 Class A, AS/NZS 3548 Class A, VCCI Class A,
EN61000-3-2, EN61000-3-3
Immunity
EN 55024
Output Specifications
Output Voltage
54.5V + 0.1V dc at 25°C
Output Regulation
+ 1%
Output Noise and Ripple
< 100mV p-p over frequency bandwidth of 30Hz - 30MHz
Output Transient Response
< 5% at load variation 10-90%
90-10% Recover Time < 2msec
Output Overcurrent Protection
Between 105% - 130% full load
Output Overvoltage Protection
User definable to less than 59V
Output Connections
Unearthed positive (common) and negative connections
DUA1715-0AAA02.book  Page 108  Wednesday, March 23, 2005  11:17 AM