3com 5500-ei pwr Guía De Instalación Rápida

Descargar
Página de 118
64
C
HAPTER
 5: P
ROBLEM
 S
OLVING
Power cycle the unit. To do this, remove and reconnect the AC mains 
supply. If the unit has no AC main supply, remove and reconnect the DC 
RPS supply.
If another fan failure warning message is generated via the Command 
Line Interface or the Web interface, return the unit to 3Com.
Unit fails, no SNMP fan failure message is received
Power cycle the unit. To do this, remove and reconnect the AC mains 
supply. If the unit has no AC mains supply, remove and reconnect the DC 
RPS supply.
Check the command line interface (display logbuffer command) 
to determine whether a thermal shutdown has occurred.
If no, return the unit:
If yes, check that:
The air vents are not obstructed.
The ambient temperatures and environmental conditions meet those 
specified in 
.
Power cycle the unit. If a further thermal shutdown occurs, and all 
environmental conditions are satisfactory, return the unit to 3Com.
Error message indicating that the SFP transceiver is invalid
The Switch has identified that the SFP does not meet the minimum 
requirements for the Switch and has disabled the port. To correct this 
problem, completely remove the SFP and replace it with a 3Com 
approved SFP. See 
 on 
Error message indicating that the SFP transceiver is faulty
To correct this problem, completely remove the SFP and then reinsert it. 
Alternatively, insert another identical SFP. If the problem persists, contact 
3Com Technical Support.
Solving 
Communication 
Problems
If you experience communication problems with the Switch, ensure that:
The Switch IP address and Management VLAN ID has been 
configured.
DUA1715-0AAA02.book  Page 64  Wednesday, March 23, 2005  11:17 AM