3com 5500-ei pwr Instruccion De Instalación
![3com](https://files.manualsbrain.com/attachments/960452ff43b9899cbcffced60c87abf956e7967a/common/fit/150/50/f6ac125d7af2cf40fec58935fa6d4bf71457a57efe50bee91208a434f325/brand_logo.jpeg)
1-7
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enter Ethernet interface view
interface interface-type
interface-number
interface-number
Required
Enable LLDP polling and set
the polling interval
the polling interval
lldp check-change-interval value
Optional, the
configuration applies to
the current port only.
configuration applies to
the current port only.
Disabled by default
Configuring the Parameters Concerning LLDPDU Sending
Configuring time-related parameters
Follow these steps to set time-related parameters:
To do…
Use the command…
Remarks
Enter system view
System-view
—
Set the interval to send
LLDPDUs
LLDPDUs
lldp timer tx-interval value
Optional
30 seconds by default
Set the delay period to send
LLDPDUs
LLDPDUs
lldp timer tx-delay value
Optional
2 seconds by default
To enable local device information to be updated on neighboring devices before being aged out, make
sure the interval to send LLDPDUs is shorter than the TTL of the local device information.
Setting the number of the LLDPDUs to be sent when a new neighboring device is detected
Follow these steps to set the number of the LLDPDUs to be sent when a new neighboring device is
detected
To do…
Use the command…
Remarks
Enter system view
system-view
—
Set the number of the
LLDPDUs to be sent
successively when a new
neighboring device is detected
LLDPDUs to be sent
successively when a new
neighboring device is detected
lldp fast-count value
Optional
3 by default
Configuring the Encapsulation Format for LLDPDUs
LLDPDUs can be encapsulated in Ethernet II or SNAP frames.
z
With Ethernet II encapsulation configured, an LLDP port sends LLDPDUs in Ethernet II frames and
processes only Ethernet II encapsulated incoming LLDPDUs.