3com 5500-ei pwr Guía De Referencia
3-10
Table 3-7 Description on the fields of display transceiver diagnosis interface
Field
Description
transceiver diagnostic information
Digital diagnosis information of the transceiver
carried by an interface
carried by an interface
Current diagnostic parameters
Current diagnostic parameters
Temp.(°C)
Digital diagnosis parameter-temperature, in °C,
with the precision to 1°C.
with the precision to 1°C.
Voltage(V)
Digital diagnosis parameter-voltage, in V, with
the precision to 0.01 V.
the precision to 0.01 V.
Bias(mA)
Digital diagnosis parameter-bias current, in mA,
with the precision to 0.01 mA.
with the precision to 0.01 mA.
RX power(dBM)
Digital diagnosis parameter-RX power, in dBM,
with the precision to 0.01 dBM.
with the precision to 0.01 dBM.
TX power(dBM)
Digital diagnosis parameter-TX power, in dBM,
with the precision to 0.01 dBM.
with the precision to 0.01 dBM.
display transceiver interface
Syntax
display transceiver interface [ interface-type interface-number ]
View
Any view
Parameters
interface-type interface-number: Interface type and interface number.
Description
Use the display transceiver interface command to display main parameters of a single or all
transceivers.
Examples
# Display main parameters of the pluggable transceiver on interface GigabitEthernet 1/0/25.
<Sysname> display transceiver interface gigabitethernet 1/0/25
GigabitEthernet1/0/25 transceiver information:
Transceiver Type : 1000_BASE_LX_SFP
Connector Type : LC
Wavelength(nm) : 1310
Transfer Distance(km) : 10(9um)
Digital Diagnostic Monitoring : YES
Vendor Name : H3C
Ordering Name : N/A