3com 5500-ei pwr Guía De Referencia

Descargar
Página de 1314
 
1-19 
Parameters 
Interval: Interval (in seconds) to perform statistics on port information. This argument ranges from 5 to 
300 (in step of 5) and is 300 by default.  
Description 
Use the flow-interval command to set the interval to perform statistics on port information.  
Use the undo flow-interval command to restore the default interval. 
By default, this interval is 300 seconds.  
When you use the display interface interface-type interface-number command to display the 
information of a port, the system performs statistical analysis on the traffic flow passing through the port 
during the specified interval and displays the average rates in the interval. For example, if you set the 
interval to 100 seconds, the displayed information is as follows: 
 Last 100 seconds input:  0 packets/sec 0 bytes/sec 
 Last 100 seconds output:  0 packets/sec 0 bytes/sec 
Related commands: display interface
Examples 
# Set the interval to perform statistics on the Ethernet 1/0/1 port to 100 seconds. 
<Sysname> system-view 
System View: return to User View with Ctrl+Z. 
[Sysname] interface ethernet 1/0/1 
[Sysname-Ethernet1/0/1] flow-interval 100 
giant-frame statistics enable  
Syntax 
giant-frame statistics enable 
undo giant-frame statistics enable 
View 
System view 
Parameters 
None 
Description 
Use the giant-frame statistics enable command to enable the giant-frame statistics function.  
Use the undo giant-frame statistics enable command to disable the giant-frame statistics function. 
By default, the giant-frame statistics function is not enabled.  
After enabling the giant-frame statistics function, you can use the display interface command to view 
the statistics about giant frames.