Field 
Description 
Linked with event  
Event index corresponding to an alarm 
When startup enables: risingOrFallingAlarm 
The condition under which an alarm is triggered, 
which can be: 
risingOrFallingAlarm: An alarm is triggered 
when the rising or falling threshold is 
reached. 
risingAlarm: An alarm is triggered when the 
rising threshold is reached. 
FallingAlarm: An alarm is triggered when the 
falling threshold is reached. 
This entry will exist: forever 
Existing period. This entry can exist forever or 
exist in the specified cycle 
Latest value 
The value of the latest sample 
 
display rmon statistics 
Syntax 
display rmon statistics [ interface-type interface-number | unit unit-number 
View 
Any view 
Parameters 
interface-type: Interface type. 
interface-number: Interface number. 
unit unit-number: Specifies a unit number. 
Description 
Use the display rmon statistics command to display the RMON statistics on a specified port or a 
specified unit. If you do not specify the port or the unit, this command displays the RMON statistics on all 
the ports or units. 
The information displayed includes the number of: 
Collisions 
Packets with CRC errors 
Undersize/Oversize packets 
Broadcast/multicast packets 
Received bytes 
Received packets 
Related commands: rmon statistics
Examples 
# Display the RMON statistics on Ethernet 1/0/1 port. 
<Sysname> display rmon statistics Ethernet 1/0/1 
Statistics entry 1 owned by user1-rmon is VALID.