3com 5500-ei pwr Guía De Referencia

Descargar
Página de 1314
 
2-14 
Falling threshold: 5 
Event 1 is triggered when the change ratio is larger than the rising threshold. 
Event 2 is triggered when the change ratio is less than the falling threshold. 
The alarm entry is valid forever. 
Entry owner: user1 
<Sysname> system-view 
System View: return to User View with Ctrl+Z. 
[Sysname] interface Ethernet 1/0/1 
[Sysname-Ethernet1/0/1] rmon statistics 1 
[Sysname-Ethernet1/0/1] quit 
[Sysname] rmon prialarm 2 ((.1.3.6.1.2.1.16.1.1.1.4.1)*100) test 10 changeratio 
rising_threshold 50 1 falling_threshold 5 2 entrytype forever owner user1 
 # Remove the extended alarm entry numbered 2 from the extended alarm table. 
[Sysname] undo rmon prialarm 2 
rmon statistics 
Syntax 
rmon statistics entry-number owner text ] 
undo rmon statistics entry-number 
View 
Ethernet port view 
Parameters 
entry-number: Statistics entry Index, in the range 1 to 65535. 
owner text: Specifies the owner of the entry, a string of 1 to 127 characters. 
Description 
Use the rmon statistics command to add an entry to the statistics table. If you do not specify the owner 
text keyword/argument combination, the owner of the entry is displayed as “null”. 
Use the undo rmon statistics command to remove an entry from the statistics table. 
The RMON statistics management function is used to take statistics of the usage of the monitored ports 
and errors occurred on them. The statistics includes the number of the following items: 
Collisions 
Packets with CRC errors 
Undersize/Oversize packets 
Broadcast/Multicast packets 
Received packets 
Received bytes