3com 7000 Manual Suplementario

Descargar
Página de 516
ILMI Setup
139
Update ILMI Channel
Polling Interval
Updates and saves the ILMI channel polling interval for the specified port 
in the CoreBuilder 7000 family ATM switch. The ILMI polling interval is 
normally set to 30 seconds. For more information, “ILMI Connectivity Polling” on page 41 in the Operations Guide.
Command Actions
Command Result
Example
Enter:
 1 1 8 5 4 3.2
 
30
The following message is displayed:
ILMI polling timeout reconfigured
The polling interval of port 2 in slot 3 is set to 30 seconds and is saved to 
flash.
Enter the menu sequence: 
(1) SYS: Platform config
  (1) SET: Switch setup
    (8) IME: ILMI setup
     (5) POL: Polling setup
       (4) STO: Set&Save Polling timeout
Enter a parameter at the prompt
Parameter
Format or Range
Port ID
slot.port
Polling interval 
Range: 5–1800 seconds
Direct access sequence:
1 1 8 5 4 
[parameters]
System action taken:
The polling interval for the specified port is updated 
immediately and is saved in flash.
System message display:
ILMI polling timeout reconfigured