Signaling Setup
205
Update Signaling
Protocol Version
Updates the signaling protocol version of the ports of the CoreBuilder 
7000 family ATM switch. 
This command causes the new protocol version to be activated in the 
current session. The new value is not stored in flash until you use the SAV 
command (“Save Signaling Protocol Configuration” on page 206). 
If the new value of the protocol version is not stored in flash, the system 
reverts to the previous value of the protocol version the next time it 
reboots.
Command Actions
Command Result
Example
Enter: 
1 1 4 5 4 3.2 1 
The following message is displayed:
Parameter was set. Use 'SAVE' to save it on flash.
The signaling protocol version for port 3.2 is updated to 3.1.
Enter the menu sequence: 
(1) SYS: Platform config
  (1) SET: Switch setup
    (4) SIG: Signaling setup
      (5) SPS: Signaling protocol setup
        (4) SPV: Set protocol version
Enter a parameter at the prompt
Parameter
Format or Range
Port ID 
slot.port (
0.0
 for all ports)
Protocol version 
0
 for version 3.0
1
 for version 3.1
2
 for version 4.0
Direct access sequence:
1 1 4 5 4 
[parameters]
System action taken:
The signaling protocol version is updated for the 
specified port.
System message display: