MPOA Devices 
Configuration
The switch allows configuration of MPOA entities: MPS and MPC. The 
configuration is general so that all MPSs and MPCs that request 
configuration receive the same parameters.
Display Current MPS
Configuration
Displays all the current settings of the MPS variables.
Command Actions
Command Result
Example
Enter: 
2 5 1 1
The following information is displayed: 
Enter menu sequence: 
(2) LEM: LAN Emulation
 (5) MPA: MPOA Devices Configuration
  (1) MPS: MPOA Server Configuration
(1) DIS: Display current config
Direct access sequence:
2 5 1 1
System action taken:
All the current settings of the MPS variables are 
displayed.
System message display:
Information is displayed as shown in the example 
below.
MPOA Server Configuration
-------------------------
MPS-p1
keep-alive time:
10 (seconds)
MPS-p2
keep-alive lifetime:
35 (seconds)
MPS-p3
internetwork-layer protocols:
{}
MPS-p4
MPS initial retry time:
5 (seconds)
MPS-p5
MPS retry time maximum:
40 (seconds)
MPS-p6
MPS give up time:
40 (seconds)
MPS-p7
default holding time:
20 (minutes)