3com 7000 Manual Suplementario

Descargar
Página de 516
402
C
HAPTER
 13: C
ONFIGURING
 
AND
 M
ANAGING
 PNNI (F
OR
 
THE
 E
XTENDED
 V
ERSION
 O
NLY
)
Set PTSE Lifetime
Factor
Sets the PTSE lifetime factor value. The PTSE lifetime factor is the value 
used to calculate the initial lifetime of a PTSE. The PTSE refresh interval is 
multiplied by this percentage to obtain the initial lifetime factor. A change 
to the PTSE lifetime factor value takes place after the next reboot.
Command Actions
Command Result
Example
Enter: 
1 1 10 4 3 4 6 150
The following message is displayed:
Default Value is 200, new value is 150
Press ENTER to continue...
Enter menu sequence: 
(1) SYS: Platform config
(1) SET: Switch setup
(10) PNI: PNNI Setup
(4) CFP: Configure PNNI
(3) NCF: Node Configuration
(4) TIM: Timers
(6) PLT: PTSE Lifetime Factor
Enter a parameter at the prompt
Parameter
Format or Range
lifetime factor
101% - 1000%
Direct access sequence:
1 1 10 4 3 4 6 
[parameters]
System action taken:
The Hello inactivity factor is displayed and is updated 
to its new value.
System message display:
Default value is <x>, new value is <y>