3com 7000 Manual Suplementario

Descargar
Página de 516
Setting Optimization Metrics
417
Set Optimization for
CBR
Updates the Constant Bit Rate (CBR) optimization parameter. A change to 
the CBR optimization parameter takes place immediately. 
Command Actions
Command Result
Example
Enter: 
1 1 10 4 3 5 2 1 2
The following message is displayed:
Default Value is ‘3 - opt_ctd’, New value is ‘2 - opt_av_cr’
Press ENTER to continue...
The value of the CBR optimization parameter is updated.
Enter menu sequence: 
(1) SYS: Platform config
(1) SET: Switch setup
(10) PNI: PNNI Setup
(4) CFP: Configure PNNI
(3) NCF: Node Configuration
(5) OPT: Optimization Metrics
(2) SOP: Set Optimization
Metrics
(1) OCR: Optimization for CBR
Enter a parameter at the prompt
Parameter
Format or Range
constant bit rate
0 - 6
Direct access sequence:
1 1 10 4 3 5 2 1 
[parameters]
System action taken:
The CBR optimization parameter is displayed and is 
updated to its new value.
System message display:
Default value is <x>, new value is 
<y>.