ATM Cabling
113
*Maximum attenuation includes cable attenuation and the loss induced 
by other components such as connectors, splices, and the mating of 
unlike fiber types. Although some 2 km cable plants have a total 
attenuation of less than 11.0 dB, the 2 km interstation distance must be 
maintained to comply with modal bandwidth requirements.
Calculating Insertion
Losses for Unlike
Fibers
If unlike fibers are mated in the cable plant, calculate insertion losses to 
be certain that the cable plant does not exceed the maximum attenuation 
value listed in Table 25. To calculate the insertion loss, consider the types 
of fiber in the cable plant and the connectors or splices used to join them. 
Compare the result to the maximum attenuation value listed in Table 25. 
If the result is greater than the value in the table, use only like fibers in the 
cable plant.
Refer to Table 27 for the insertion losses of the fibers themselves. Use 
Table 28, which lists the losses for connectors, cables, and splices, if the 
specifications for these components are not available.
Use Table 27 for fiber-to-fiber connections only, not for power launched 
from a transmitter.
Maximum distance between nodes
2 km
Output power (from transmitter)
19 dB minimum
14 dB maximum
Receive power
30 dB minimum sensitivity
14 dB maximum sensitivity
Table 26   Alternate Multi-mode Fiber Types
Core (µm)
Cladding (µm)
Numerical Aperture
50
125
0.20
50
125
0.22
85
125
0.28
100
140
0.29
Table 25   Standard Multi-mode Fiber Specification (continued)