Verifying Maximum
Attenuation for
Mixed Fibers
If you mix Category 1 and Category 2 receivers and transmitters, use 
Table 30 to verify the maximum attenuation for each possible 
combination.
*This combination is dispersion-limited rather than loss-limited. The 
expected maximum length is approximately 35 km.
Example. If a Category 2 transmitter is outputting to a Category 1 
receiver, the maximum attenuation is 26.0.
DS-3 Coax Cables
Connect the CoreBuilder 7000 DS-3 interface by a 75 Ohm coaxial cable 
that complies with DS-3 standards. The maximum cable length is 450 
feet. To connect the DS-3 interface:
Prepare two coax cables - one for Tx and one for Rx. You may want to 
mark the ends of the cables to identify them easily.
Connect both cables to the DS-3 BNC connectors on the CoreBuilder 
interface. Make sure to connect Rx and Tx cables according to what is 
indicated on the interface front panel.
Connect the two cables at the other end according to the opposite of the 
first connection Rx to Tx and Tx to Rx.
Ethernet Cabling
The Ethernet port of the CoreBuilder allows you to connect the 
CoreBuilder to an Ethernet network for Network Management Station 
(NMS) connectivity (such as Transcend™). The Ethernet port is a standard 
RJ-45 connection of a terminal side.
Follow these guidelines for 10BASE-T cabling:
Use only copper, unshielded twisted-pair (UTP) wiring. Do not use flat, 
multiconductor cable (for example, silver satin), which is often 
identified by solid colors such as red, green, yellow, or black.
Table 30   Acceptable Cable Plants for Combination of Categories 1 and 2
Output Category Input Category
Minimum Loss 
(dB)
Maximum 
Attenuation (dB)
1
1
0.0
10.0
1*
2*
1.0
16.0
2
1
14.0
26.0
2
2
15.0
32.0