3com 140m Guía Del Usuario

Descargar
Página de 110
6-2
C
HAPTER
 6: P
ROBLEM
 S
OLVING
Solving Problems With the Switch
Power LED not lit. Check your power adapter 
connection. If there is still no power, you may have a 
faulty power adapter which needs replacing with 
another OfficeConnect power adapter. Do not use 
any other power adapter with the switch.
Alert LED remains lit after self-test. Power off the 
switch, wait about five seconds and then power on 
the switch so that it performs its self-test again. If 
the Alert LED still remains lit after self-test, there is a 
problem with the switch. Contact your supplier.
Alert LED continually lit during use. Use the Alert 
LED page in the web interface to see what condition 
is causing it to light, refer to 
If you are trying to view the Alert LED page over the 
network but cannot communicate with the switch, it 
may be because of a broadcast storm (excessive 
amounts of broadcast frames). Try to communicate 
through the console port instead.
If the Alert LED page shows that Broadcast Traffic or 
Error Rate conditions are causing the Alert LED the 
light, it may be that there is:
A network loop — Each piece of equipment 
needs only one connection to your switch.
Excessive amounts of broadcast frames — Some 
pieces of network equipment operate by sending 
out broadcast frames regularly. Refer to the 
documentation that accompanies the piece of 
network equipment.
To isolate the port on which the problem is occuring, 
remove the port connections one at a time (starting 
with the 100BASE-TX port), waiting about a minute 
between each port. If the Alert LED goes off, you 
have found the port.
If the Alert LED is still lit after removing all of your 
connections, there may be a problem with your 
switch. Power it off, wait about 5 seconds and then 
power it on. If the Alert LED comes back on 
continually, contact your supplier.