3com S7906E Instruccion De Instalación

Descargar
Página de 2621
 
1-23 
Total connections:  1,  1 up,  0 down 
ce-intf             state destination     tr-label  rcv-label tnl-policy 
Vlan10               up    192.3.3.3       100       200       default    
# Display SVC L2VPN connection information on PE 2. 
[PE2] display mpls static-l2vc 
Total connections:  1,  1 up,  0 down 
ce-intf             state destination     tr-label  rcv-label tnl-policy 
Vlan20               up    192.2.2.2       200       100       default 
# Ping CE 2 from CE 1. 
[CE1] ping 100.1.1.2 
  PING 100.1.1.2: 56  data bytes, press CTRL_C to break 
    Reply from 100.1.1.2: bytes=56 Sequence=1 ttl=255 time=150 ms 
    Reply from 100.1.1.2: bytes=56 Sequence=2 ttl=255 time=130 ms 
    Reply from 100.1.1.2: bytes=56 Sequence=3 ttl=255 time=130 ms 
    Reply from 100.1.1.2: bytes=56 Sequence=4 ttl=255 time=140 ms 
    Reply from 100.1.1.2: bytes=56 Sequence=5 ttl=255 time=80 ms 
  --- 100.1.1.2 ping statistics --- 
    5 packet(s) transmitted 
    5 packet(s) received 
    0.00% packet loss 
    round-trip min/avg/max = 80/126/150 ms  
Example for Configuring Martini MPLS L2VPN  
Network requirements 
CEs are connected to PEs through VLAN interfaces. 
A Martini MPLS L2VPN is established between CE 1 and CE 2. 
Figure 1-5 Network diagram for configuring Martini MPLS L2VPN 
 
Device  Interface IP 
address 
Device  Interface IP 
address 
CE 1 
Vlan-int10 
100.1.1.1/24 P 
Loop0 192.4.4.4/32 
PE 1 
Loop0 
192.2.2.2/32 
 
Vlan-int20 
10.1.1.2/24 
 
Vlan-int20 10.1.1.1/24 
 
Vlan-int30 10.2.2.2/24 
CE 2 
Vlan-int10 
100.1.1.2/24 PE 
2  Loop0 192.3.3.3/32 
   
 Vlan-int30 
10.2.2.1/24 
 
Configuration procedure 
1)  Configure CE 1