3com S7906E Instruccion De Instalación
1-14
Configuring a TCP Test
A TCP test is used to test the TCP connection between the client and the specified port on the NQA
server and the setup time for the connection, thus judge the availability and performance of the services
provided on the specified port on the server.
Configuration prerequisites
A TCP test requires cooperation between the NQA server and the NQA client. The TCP listening
function needs to be configured on the NQA server before the TCP test. For the configuration of the
TCP listening function, refer to
Configuring a TCP test
Follow these steps to configure a TCP test:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enter NQA test group view
nqa entry admin-name
operation-tag
operation-tag
—
Configure the test type as TCP
and enter test type view
and enter test type view
type tcp
Required
Configure the destination
address for a test operation
address for a test operation
destination ip ip-address
Required
By default, no destination IP
address is configured for a test
operation.
address is configured for a test
operation.
The destination address must
be the IP address of the
listening service configured on
the NQA server.
be the IP address of the
listening service configured on
the NQA server.
Configure the destination port
destination port port-number
Required
By default, no destination port
number is configured for a test
operation.
number is configured for a test
operation.
The destination port number
must be consistent with port
number of the listening service
configured on the NQA server.
must be consistent with port
number of the listening service
configured on the NQA server.
Configure the source IP
address of a probe request in a
test operation
address of a probe request in a
test operation
source ip ip-address
Optional
By default, no source IP
address is specified.
address is specified.
The source IP address must be
that of an interface on the
device and the interface must
be up. Otherwise, the test will
fail.
that of an interface on the
device and the interface must
be up. Otherwise, the test will
fail.
Configure common optional
parameters
parameters
Optional