3com S7906E Instruccion De Instalación

Descargar
Página de 2621
 
1-19 
To do… 
Use the command… 
Remarks 
Configure the destination 
address for a test operation 
destination ip ip-address 
Required 
By default, no destination IP 
address is configured for a test 
operation. 
Configure the source IP 
address of a probe request in a 
test operation 
source ip ip-address 
Optional 
By default, no source IP 
address is specified. 
The source IP address must be 
that of an interface on the 
device and the interface must 
be up. Otherwise, the test will 
fail. 
Configure common optional 
parameters 
Refer to
Optional 
 
Configuring the Collaboration Function 
Collaboration is implemented by establishing collaboration entries to monitor the detection results of the 
current test group. If the number of consecutive probe failures reaches the threshold, the configured 
action is triggered. 
Follow these steps to configure the collaboration function: 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Enter NQA test group view 
nqa entry admin-name 
operation-tag 
— 
Enter test type view of the test 
group 
type { dhcp | dlsw | dns | ftp | 
http | icmp-echo | snmp | tcp | 
udp-echo } 
The collaboration function is 
not supported in UDP jitter 
and voice tests. 
Create a collaboration entry 
reaction item-num 
checked-element probe-fail 
threshold-type
 consecutive
 
occurrences action-type 
none | trigger-only } ] 
Required 
Not created by default. 
Exit to system view 
quit 
— 
Create a track entry and associate 
it with the specified collaboration 
entry of the NQA test group 
track entry-number nqa entry 
admin-name operation-tag 
reaction item-num 
Required 
Not created by default. 
 
 
You cannot modify the content of a reaction entry using the reaction command after the 
collaboration entry is created. 
The collaboration function is not supported in a UDP jitter or voice test.