3com S7906E Instruccion De Instalación

Descargar
Página de 2621
 
1-21 
 Actual frequency: 100.0000 Hz  
 Clock precision: 2^18 
 Clock offset: 0.0000 ms  
 Root delay: 31.00 ms  
 Root dispersion: 8.31 ms  
 Peer dispersion: 34.30 ms  
 Reference time: 16:01:51.713 UTC Sep 19 2005 (C6D95F6F.B6872B02) 
As shown above, Switch D has been synchronized to Switch C, and the clock stratum level of Switch D 
is 3, while that of Switch C is 2.  
# View the NTP session information of Switch D, which shows that an association has been set up 
between Switch D and Switch C.  
[SwitchD-Vlan-interface2] display ntp-service sessions 
      source    reference    stra  reach  poll  now  offset   delay  disper 
************************************************************************** 
[1234] 3.0.1.31  127.127.1.0   2   254     64    62   -16.0    32.0   16.6 
note: 1 source(master),2 source(peer),3 selected,4 candidate,5 configured 
Total associations :  1 
Configuring NTP Multicast Mode 
Network requirements 
Switch C’s local clock is to be used as a reference source, with the stratum level of 2. 
Switch C works in the multicast server mode and sends out multicast messages from 
VLAN-interface 2. 
Switch A and Switch D work in the multicast client mode and receive multicast messages through 
VLAN-interface 3 and VLAN-interface 2 respectively. 
Figure 1-10 Network diagram for NTP multicast mode configuration 
Vlan-int3
1.0.1.11/24
Vlan-int3
1.0.1.10/24
Vlan-int2
3.0.1.31/24
Vlan-int2
3.0.1.32/24
Vlan-int2
3.0.1.30/24
Switch A
Switch B
Switch C
Switch D
 
 
Configuration procedure 
1)  Configuration on Switch C: 
# Specify the local clock as the reference source, with the stratum level of 2.  
<SwitchC> system-view 
[SwitchC] ntp-service refclock-master 2