3com S7906E Guía De Instalación Rápida

Descargar
Página de 155
 
3-19 
Figure 3-21 Cable fixing example 
(1)
(2)
(3)
(4)
 
(1) Flat washer
 
(2) Flat washer 
(3) Spring washer 
(4) Fastening nut 
 
Fix the terminal of harder power cables to free the terminal and the cable from stress; 
No tapping screw can be used to fasten the cabling terminals; 
The power cables of the same type and in the same direction should be bound together and kept 
clean and straight; 
Follow the parameters defined in the following table for binding cables with ties. 
Table 3-4 Tie-binding parameters 
Cable bundle diameter 
Space between bundles 
10 mm (0.39 in.) 
80 mm to 150 mm (3.15 in. to 5.91 in.) 
10 mm to 30 mm (0.39 in. to 1.18 in.) 
150 mm to 200 mm (5.91 in. to 7.87 in.) 
30 mm (1.18 in.) 
200 mm to 300 mm (7.87 in. to 11.81 in.) 
 
No cable or bundle can tie a knot; 
The metal parts of crimping cold-pressed terminal blocks (such as air switch) cannot stretch 
beyond the blocks. 
Checking the Installation 
 
 
Confirm that you have turned off the power before check; otherwise, improper connection will hurt 
people or the component of the switch. 
 
After installing the switch, please check if the items listed in the following table are normal.