3com 3031 Instruccion De Instalación

Descargar
Página de 1122
160
C
HAPTER
 14: WAN I
NTERFACE
 C
ONFIGURATION
will automatically generate a synchronous serial interface accordingly whenever a 
channel set is formed.
Setting Length/Attenuation for Transmission Line
If a T1-F interface is connected to the transmission lines of various lengths, you 
should match attenuation or waveform of the interface signals with the 
transmission lines.
Perform the following configuration in T1-F interface view.
By default, attenuation matched a T1-F interface is 
long 0db
.
Setting Line Code Format
T1-F interface supports line code formats AMI (Alternate Mark Inversion) and B8ZS 
(Bipolar 8-Zero Substitution).
Perform the following configuration in T1-F interface view.
The line code format for an T1-F interface defaults to 
b8zs
.
Setting Line Clock
If T1-F interface is used as DCE, the 
slave
 clock should be selected. If it is used as 
DTE, the 
master
 clock should be selected. 
If the T1-F interfaces of two routers are directly connected, they must respectively 
work in 
slave
 and 
master
 clock modes. If the T1-F interface of the router is 
connected to an exchange, however, the exchange is working as DCE and 
provides clock, so the interface of the router should work in 
master
 clock mode. 
Perform the following configuration in T1-F interface view.
Table 202   Setting length/attenuation of transmission line on a T1-F interface
Operation
Command
Set the T1-F interface to use long-distance 
transmission line
ft1 cable long decibel
Set the T1-F interface to use short-distance 
transmission line
ft1 cable short length
Restore the default setting of the transmission 
line for the T1-F interface
undo ft1 cable
Table 203   Setting line code format for T1-F interface
Operation
Command
Set line code format for a T1-F interface
ft1 code { ami | b8zs }
Restore the default line code format for a T1-F 
interface
undo ft1 code
Table 204   Setting line clock for a T1-F interface
Operation
Command
Set line clock for a T1-F interface
ft1 clock { master | slave }