3com 3031 Instruccion De Instalación

Descargar
Página de 1122
Typical MPLS L2VPN Configuration Example
765
Networking diagram
Figure 189   Networking for Kompella configuration
Configuration procedure
Configure PE-A (in similar way for PE-C):
Configure LSR ID, enable MPLS L2VPN.
[3Com]mpls lsr-id 192.1.1.1 
[3Com]mpls
[3Com]mpls l2vpn
Assign an address to the loopback interface.
[3Com]interface loopback 0 
[3Com-LoopBack0]ip address 192.1.1.1 255.255.255.255 
Configure serial interface. 
[3Com-LoopBack0]interface serial 3/0/0 
[3Com-Serial3/0/0]ip address 168.1.1.1 255.255.0.0 
[3Com-Serial3/0/0]mpls ldp enable 
Configure CE interface for CE-A. 
[3Com]interface atm0/0/0.1
[3Com-Atm0/0/0.1]pvc CEA-CEB 100/101
[3Com-Atm0/0/0.1]interface atm0.2
[3Com-Atm0/0/0.2]pvc CEA-CEC 100/102
Reserve PVC for future CE. 
[3Com-Atm0/0/0.1]interface atm0/0/0.3
[3Com-Atm0/0/0.3]pvc CEA-CED 100/103
[3Com-Atm0/0/0.3]interface atm0/0/0.4
[3Com-Atm0/0/0.4]pvc CEA-CEE 100/104
f
Configure CE interface for CE-B. 
[3Com]interface atm1/0/0.1 
[3Com-Atm1/0/0.1]pvc CEB-CEA 200/101 
[3Com]interface atm1/0/0.2 
[3Com-Atm1/0/0.2]pvc CEB-CEC 200/102 
Reserve PVC for future CE. 
[3Com]interface atm1/0/0.3 
[3Com-Atm1/0/0.3]pvc CEB-CED 200/103 
[3Com]interface atm1/0/0.4 
[3Com-Atm1/0/0.4]pvc CEB-CEE 200/104 
Local connection
Remote connection
CE-A
CE-B
CE-C
PE-A
PE-B
P
atm0/0/0
s1/0/0
s0/0/0
s0/0/0
atm0/0/0
atm1/0/0
s3/0/0
PPP
Remote connection