Connecting the PGND
w
WARNING: The normal connection of the protection ground (PGND) on the 
router chassis is an essential safeguard against the lightning shocks and 
interference. You must correctly connect the PGND when installing or using the 
router.
As shown in the following figure, the router provides a protection ground (PGND) 
screw at the top right-rear of the chassis. You must securely connect it to the earth 
ground to safely channel faradic current and leakage electricity to the ground and 
have the device less susceptible to electromagnetic interference (EMI).This PGND 
wire can also protect the router against the lightning caused by the connection 
with the external network lines, such as E1/T1 line, ISDN/PSTN line.
n
No protection grounding wire is delivered together with the MSR 30-11.
The grounding screw of H3C MSR 30 Series Router, which is marked with 
grounding label, is located near the AC power socket and its switch on the rear 
panel of the chassis, as shown in the following figure:
Figure 14   Grounding terminal of the router
Use a PGND wire to connect the screw to the earth ground, and the grounding 
resistance should not be greater than 5-ohm. Likewise, if the router is installed in a 
19-inch standard rack, this rack is required to be grounded too.
w
WARNING: When the router is in normal operation, it is required to be well 
grounded. Otherwise, the router cannot reliably avoid lightning, which may 
damage the router itself and even the peer device.
Connecting the Power 
Cord
Base on power supply mode, the MSR 30 Series Routers have three models: DC, 
AC and PoE. You can choose suitable ones as needed.
Power Input and PGND
Table 20   Power input and PGND of the H3C MSR series routers
Item Description 
Power input 
AC-powered: provide 100 VAC to 240 VAC input socket 
DC-powered: provide -60 VDC to -48 VDC input socket 
PGND 
Ground terminal available: connected to the earth ground 