Preh mci touchkey Manual Suplementario

Descargar
Página de 40
 
PrehKeyTec GmbH 
TK-TechDoc_RevB_en.doc - 2008-07-31 
Page  39/40 
Technical Data 
 
Electronics: 
 
Supply voltage: 
 
+5 V ± 5% 
Current consumption: 
< 500 mA 
Interface: 
  USB 
LCD TouchKey: 
 
5.7 inch monochrome with 320 x 240 pixel 
Backlight: 
  LED 
Touch 
panel: 
  4-wire 
resistive 
 
 
Temperature and Environment Ratings: 
 
Operational temperature:  0°C to 50°C 
Air pressure:  
 
700 hPa to 1060 hPa 
Storage & transportation:  -30°C to 60°C 
Climatic class: 
 
DIN-IEC 68, part 1, appendix A 
Protection class: 
 
IP 54 from top 
 
 
Materials: 
 
Housing: 
  ABS 
Guide 
frame: 
  Polystrol 
Switching membrane: 
Polyester 
Spring elements: 
 
Elastomer 
Textile 
filter: 
  Trevira 
Keys and keycaps:   
PBT / POM / PC / PMMA 
TouchKey:   
 
ABS / PBT-GF30 / PS 
 
 
Certifications: 
 
ESD/EMC/EMV:  
CE 
Approval 
Emissions:   
 
EN55022, FCC Subpart 15, Class B 
Interface Immunity:  
Electrostatic discharge immunity according to 
EN 61000-4-2, resistance limit 8 kV (contact discharge), 
13 kV (air discharge)  
against high frequency electromagnetic fields; penetration 
test value = 10 V/m