GE jkp86shss Prospecto

Descargar
Página de 2
GE Appliances
Specification Revised 5/04
320358
JKP86SH – GE 27" Built-In Double Microwave/Thermal Oven 
Dimensions (in inches)
(Must support 275 lbs.)
6015 Built-In MW/Double Ovens
(Pub. 1-G003 pg 105B) May 12, 1993
Built-In Microwave/Double Ovens 
Dimensions (in inches)
E
Minimum
cutout location
from floor
Allow minimum of
21" for clearance
to adjacent corners,
drawers, walls, etc.
21
2" X 4" or
equiv. runners
Conduit
(49" long)
Allow 3/4" for overlap
of oven over all
edges of cutout
10 
A
D
Recommended
junction box
locations.
Locate junction
box either 5" MIN.
below cutout
floor or 48" MIN.
above cutout
floor
C
B
F
G
H
CL
Suitable
bracing 
to support
runners
18" 
Over centerline
of cabinet
2" x  4" or
equivalent
runners
Note: Cabinets installed adjacent to wall ovens must have an adhesion spec of at least a 194°F 
temperature rating.
Note: If marks, blemishes or the cutout opening is visible above the installed oven, it may be  
necessary to add wood shims under the runners and front trim until the marks or openings  
are covered.
 
 KW Rating
 
240V 
6.4
  208V 
5.1
Breaker Size
 
240V 
30 Amps
  208V 
30 Amps
Cabinet 
 
27"
  A – Cabinet Width Required 
 
27" min.
  B – Minimum Cabinet Depth 
 
23-5/8"
  C – Opening Width 
 
25" min.-25"-1/4 max.
  D – Opening Height 
 
41-1/4" max.
  E – Minimum Cutout Location from Floor 
22"
Oven
  F – Overall Depth 
 
23-5/8"
   
 
w/o trim 
41-1/8"
  G – Overall Height  
with trim 
42-1/8"
  H – Overall Width 
 
26-5/8"
Note: Cabinets installed adjacent to wall ovens must have an adhesion spec  
of at least a 194°F temperature rating.
Installation Information: Before installing, consult installation instructions 
packed with product for current dimensional data.
R
Listed by 
Underwriters 
Laboratories
For answers to your Monogram,
®
 GE Profile
 or  
GE
®
 appliance questions, visit our website at  
GEAppliances.com or call GE Answer Center
®
  
service, 800.626.2000.
Electric wall ovens are not approved for installation with a plug and receptacle. 
They must be hard wired in accordance with installation instructions.