Hotpoint rb525hct Guia De Especificaciones

Descargar
Página de 2
®
Specification Created 4/03
RB525H – Hotpoint 30" Free-Standing Electric Range 
Dimensions (in inches)
R
Listed by
Underwriters
Laboratories
All Hotpoint ranges are equipped
with an Anti-Tip device. The 
installation of this device is 
an important, required step in 
the installation of the range.
Note: Check local codes for required breaker size.
Note: 30" Electric Ranges conform to U.L. requirements for 0" spacing from
walls below countertops. Allow 1-1/2" spacing from the side of the range to
adjacent vertical walls above the cooktop surface.
Receptacle Locations: Locally approved flexible service cord or conduit
must be used because terminals are not accessible after range installation.
See shaded area in drawing for location of electrical outlet box. Recommended
outlet locations allow range to be installed directly against rear wall.
Installation Information: Before installing, consult installation instructions
packed with product for current dimensional data. 
KW Rating
240V
10.1
208V
8.0
Breaker Size
40 Amps
26-3/8*
46-3/8
1/4
29-7/8
46-1/2
CENTER LINE
2-1/4
7-1/2
7-1/2
7
5
2-1/4
3-1/2
REAR
WALL
*Dimension from wall to front of closed oven door.
Dimension from wall to the front of closed oven 
door handle is 28-1/2".
The range may be placed with
0" clearance (flush) at the back 
wall and side walls if the range
side trims extend beyond the 
cabinet fronts at least 1/4".
Self-Clean models only