Specification Revised 11/05
420491
RB790WK/CK/BK – Hotpoint 30" Free-Standing Electric Range 
Dimensions (in inches)
Listed by 
Underwriters 
Laboratories
26-3/8*
46-3/8
1/4
29-7/8
46-1/2
CENTER LINE
2-1/4
7-1/2
7-1/2
7
5
2-1/4
3-1/2
REAR
WALL
25-7/16
46-1/8
1/4
29-7/8
45-1/8
CENTER LINE
2-1/4
7-1/2
7-1/2
7
5
2-1/4
3-1/2
REAR
WALL
Note: Check local codes for required breaker size.
Effective January 1, 1996, the National Electrical Code requires 
that new construction (not existing) utilize a 4-conductor 
connection to an electric range. 
Note: 30" Electric Ranges conform to U.L. requirements for 0" 
spacing from walls below countertops. Allow 1-1/2" spacing 
from the side of the range to adjacent vertical walls above the 
cooktop surface.
Receptacle Locations: Locally approved flexible service cord 
or conduit must be used because terminals are not accessible 
after range installation. See shaded area in drawing for location 
of electrical outlet box. Recommended outlet locations allow 
range to be installed directly against rear wall.
Installation Information: Before installing, consult installation 
instructions packed with product for current dimensional data. 
 
 KW Rating
  240V
 
10.5
  208V 
7.9
Breaker Size
 
40 Amps
All Hotpoint ranges are equipped 
with an Anti-Tip device. The 
installation of this device is an 
important, required step in the 
installation of the range.
* Dimension from wall to front of closed oven door. 
Dimension from wall to the front of closed oven  
door handle is 28-1/2".
†The range may be placed with
0" clearance (flush) at the back  
wall and side walls if the range  
side trims extend beyond the  
cabinet fronts at least 1/4".
Self-Clean models only 
R