Polycom EX Guía Del Software

Descargar
Página de 300
API Guide for ViewStation EX, ViewStation FX, and VS4000 
262
www.polycom.com/videodocumentation
dcdfilter
Description
This command lets you configure the filter of the dcd serial interface control 
signal (data carrier detect). When this filter is enabled, dcd drops for 60 
seconds before changing the call state. The default setting for this signal is 
“off”. 
Syntax
dcdfilter <on|off|get>
Example
dcdfilter on
User Interface Screen Location
System Info > Admin Setup > Video Network > Advanced V.35: DCD > Filter
Parameter
Definition
on
Enables the dcd filter.
off
Disables the dcd filter.
get
Returns the current setting (on or off).