Polycom EX Manual De Referencia

Descargar
Página de 150
Chapter 2 - Technical Information
© Polycom, Inc.
27
Indicators on the PRI Network Interface Module
The tables below describe the expected behavior of the indicator 
lamps on the PRI network interface module. On the network side, 
the expected behavior depends on whether it is a T1 module or an 
E1 module.
Non-Facility 
Associated Signaling 
(NFAS)
Not supported
Special services 
(Caller ID, call 
blocking, etc.)
Not supported
Table 2-17.  PRI Network Side Indicator Lamps  
Indication
PRI T1
PRI E1
Red LED blinking
Not connected to the network, or no power to the 
upstream equipment
Red LED on
Connected to the network, but no clock sync
Yellow LED blinking
Receiving clock and 
frame sync; receiving 
RAI from the network 
with CRC errors
Yellow LED on
Receiving clock and 
frame sync,
 
waiting for 
a timer to elapse
Receiving clock and 
frame sync; receiving 
Remote Alarm 
Indication (RAI) from 
the network with no 
Cyclic Redundancy 
Check (CRC) errors
Red and yellow 
LEDs on
Receiving clock sync; 
receiving AIS Alarm 
Indication Signal
 
(unframed all-ones)
Green LED on
Synchronized with the network and ready to use
Table 2-16.  PRI T1 and E1 Network Interface Modules (Continued)
Parameter
PRI T1
PRI E1