You must use an external power supply if you use the internal CSU 
capability of the PRI T1 network interface module.
Channel Service Unit
In North America, the PRI T1 network interface module can be 
connected to an external Channel Service Unit (CSU). The CSU 
isolates the PRI from the network, and continues to transmit a signal 
to the network even if the PRI network interface module loses 
power or is disconnected. This prevents the line from being 
deactivated. A CSU is normally used only when the PRI network 
interface module is connected directly to a telephone company 
switch, not a PBX.
Outside North America, CSUs are not used with PRI network 
interface modules.
If you use an external CSU, connect an RJ-45 cable from the CPE 
equipment side of the CSU to the PRI network interface module.
ADTRAN Atlas 800 Plus E1 Module
Firmware
If you are using an ADTRAN Atlas 800 Plus E1 Module, it must use 
firmware version G03b or later. 
Channel Restarts
Wait two to three minutes after the endpoint has been powered on 
and the PRI status icon has turned green before making or receiving 
calls with the ADTRAN Atlas 800 Plus. This allows time for channel 
restarts on the ADTRAN Atlas 800 Plus E1 module. If you place a 
call before channel restarts are complete, a Network Congestion 
message appears on the system. Incoming calls during this time will 
receive a Far Site Busy message.