ViewStation EX, ViewStation FX, and VS4000 API Guide    
© Polycom, Inc. 2003
7
control the far site system, using the far site’s Command Line 
Interface.
The following table summarizes the port operation based on the 
RS-232 mode configured by each endpoint.
Flow Control
The system support hardware flow control. Users should make sure 
that hardware flow control settings are consistent between the 
systems and the external devices on both sides of the connection.
Near-Side Mode
Far-Side Mode
Resulting Operation
Control
N/A
Near-side CLI (Com-
mand Line Interface)
Pass-Thru
Control
The near-side controls 
the CLI of the far side
Pass-Thru
Pass-Thru
The data is passed in 
full-duplex mode from 
the near-side RS-232 
port to the far-side 
RS-232 port