Polycom EX Guía Del Usuario

Descargar
Página de 224
ViewStation EX, ViewStation FX, and VS4000 API Guide    
194
www.polycom.com
inverted
Sets the signal to inverted (low voltage is logic 1).
get
Displays the current setting (normal or inverted).
Example
dcd inverted
User Interface Screen Location
System Info>Admin Setup>Video Network>Advanced V.35: DCD
This screen is only accessible if you have a 
V.35/RS-449/RS-530/RS-366 network interface connected to your 
system.
dcdfilter <on|off|get>
Description
This command lets you configure the filter of the dcd serial interface 
control signal (data carrier detect). When this filter is enabled, dcd 
drops for 60 seconds before changing the call state. The default 
setting for this signal is off
on
Enables the dcd filter.
off
Disables the dcd filter.
get
Displays the current setting (on or off).
Example
dcdfilter on
User Interface Screen Location
System Info>Admin Setup>Video Network>Advanced V.35: 
DCD>Filter
This screen is only accessible if you have a 
V.35/RS-449/RS-530/RS-366 network interface connected to your 
system.
dcdfilter