   To Previous Page 
             Talker ID    GP      LC      DE
Output Data        (00-90 sec)       100%
DATA 4 I/O SETUP    <Out>    2/2
MENU : Escape
ENT : Enter
Data Fmt.
                 
V1.5 
    
V2.0
 
  
  
IEC
      1.  AAM:00 APA:00
APB:04  BOD:00
      2.  BWR:00 BWW:00 GGA:00 GLL:01
      3.  RMB:01 RMC:00 VTG:01 WCV:00
      4.  WNR:00 WPL:00  XTE:00
ZDA:01
      5.  GNS:00 GBS:01 Rnn:00
RTE:00
 
Figure 8-10 DATA 4 I/O SETUP menu (2/2) 
 
7)  Follow "DATA 1 output setting" from step 
2. 
 
 
8.5  Receiving Data from 
Personal Computer 
Loading waypoint/route data 
Waypoints and routes data can be 
downloaded from a personal computer, 
through the DATA 4 connector. 
 
1) Press 
MENU ESC9 and 5.  
2) Press    to select DATA 4 Level. 
3) Press   or    to select level of personal 
computer; RS232C or RS422.   
4) Press the 
NU/CU ENT key.   
5) Press   or    to select Com. 
6) Press    to select To Next Page. The 
DATA 4 I/O SETUP menu appears. 
To Previous Page
Baud Rate               9600 bps
Command            Stop          Start
Save Data            WPT/RTE
Command            Stop          Start
DATA 4 I/O SETUP  <Com.>    2/2
MENU : Escape
ENT : Enter
 :  Select
Load Data
           
WPT/RTE
  WPT
 
Figure 8-11 DATA 4 I/O SETUP menu (2/2) 
 
7) Press    to select Baud Rate. 
8) Press   or    to select baud rate; 4800 
bps, 9600 bps, or 19200 bps. 
9) Press the 
NU/CU ENT key.   
10) Press   or    to select WPT/RTE. 
11) Press    to select Command. Stop, on 
the same line as Command, appears in 
reverse video. 
12) Press    to select Start. The message 
shown in Figure 8-12 appears. 
Loading erases current data
and stops Route navigation
Are you sure to load ?
ENT: Yes      MENU:No
 
Figure 8-12 
 
13) Press  the 
NU/CU ENT key. The message 
shown in Figure 8-13 appears. 
Now loading
Waypoint/Route data !
MENU:Stop
 
Figure 8-13 
 
14) Operate the computer to output data. 
When data is loaded, the cursor shifts to 
Stop. 
15) Press  the 
MENU ESC key. When data is 
loaded successfully, The message shown 
in Figure 8-14 appears. 
Loading ended successfully
Press any key
 
Figure 8-14 
If data could not be loaded, the message 
shown in Figure 8-15 appears. 
Failed in loading
Invalid data
Press any key
 