10737 120800
BLU/BLK wire from TL5 to P1
WHI/GRN wire from TL4 to (WHI) Solenoid
WHI/BLU wire from TL3 to (BLK) Solenoid
WHI wire from TL2 to P2
BLK wire from TL1 to P3
FIG. 22 DIGITAL TIMER WIRING
P2037
DIGITAL BREW TIMER (Late Models)(cont.) 
SERVICE (cont.)
1.  Modifying brew volumes. To modify a brew vol-
ume, fi rst check that the SET/LOCK switch is in the 
"SET" position on the circuit board.
 
To increase a brew volume, place the ON/OFF 
switch in the "ON" position, press and hold the START 
switch until three clicks are heard. Release the switch 
and press it again one or more times. (Failure to re-
lease the switch within two seconds after the third click 
causes the volume setting to be aborted and previous 
volume setting will remain in memory.) Each time the 
switch is pressed, two seconds are added to the brew 
time period. Allow the brew cycle to fi nish in order to 
verify that the desired volume has been achieved.
 
To decrease a brew volume, place the ON/OFF 
switch in the "ON" position, press and release the 
START switch once for every two-second interval to 
be removed from the total brew time period; then im-
mediately press and hold down the START switch until 
three clicks are heard. Release the switch. (Failure to 
release the switch within two seconds after the third 
click causes the volume setting to be aborted and 
previous volume setting will remain in memory). Al-
low the brew cycle to fi nish in order to verify that the 
desired volume has been achieved.
2.  Setting brew volumes.  To set a brew volume, 
fi rst check that the SET/LOCK switch is in the "SET" 
position on the circuit board. Place the ON/OFF switch 
in the "ON" position, press and hold the START switch 
until three distinct clicks are heard and then release 
the switch. (Failure to release the switch within two 
seconds after the third click causes the volume setting 
to be aborted and previous volume setting will remain 
in memory.)
View the level of the liquid being dispensed. When 
the desired level is reached, turn the ON/OFF switch 
to "OFF". 
NOTE: Several ounces of water will continue to sy-
phon from the tank after turning the switch "OFF". 
The brewer remembers this volume and will continue 
to brew batches of this size until the volume setting 
procedure is repeated.
NOTE:  When brewing coffee, volume will decrease 
due to absorption by the coffee grounds.
3.  Setting programming disable feature. If it be-
comes necessary to prevent anyone from changing 
brew time once programmed, you can set the SET/
LOCK switch to the "LOCK" position. This will prevent 
any further programming until switch is once again 
put into the "SET" position.