ELECTRICAL HOOK-UP (All Models)
CAUTION
 – 
Improper electrical installation will damage electronic components. 
1. 
An electrician must provide electrical service.
2. 
Determine the available on-site electrical service.
3. 
Select the desired unit voltage based on the available on-site electrical service.
4. 
Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
5. 
Remove the front access panel beneath the sprayhead to gain access to the terminal block.
6. 
Feed the supply leads through the rear of the brewer.
7. 
Using the above diagrams, connect the desired electrical service to the fi eld wiring terminal block.
8. 
If wiring the machine for operation on 120/208 or 120/240 volts with a Power Supply Cord, the Power 
Supply Cord must be UL Listed Flexible Cord Type SO, SJO, SJTO, HSJO or SJOW, No. 12 AWG, 4 Con-
ductor, Rated 90° C. Attachment Plug Cap must be UL Listed, NEMA 14-20P or L14-20P Confi guration, 
Rated 125/250V, 20 AMPS. The Power Supply Cord must be at least 3 feet long and maximum 6 feet long 
(measured from Strain Relief to end of the Attachment Plug Cap).
9. 
Before proceeding, verify the voltage at the fi eld wiring terminal block.
10.  Set voltage switch to the appropriate position and replace the access panel. (DV Models Only)
11.  If plumbing is to be hooked up later be sure the brewer is disconnected from the power source.  If 
plumbing has been hooked up, the brewer is ready for Initial Set-Up.
ELECTRICAL REQUIREMENTS
39130 053107
WARNING - 
The brewer must be disconnected from the power source until specifi ed in Initial Set-Up.
Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements.
All Twins are 120/208 & 120/240V AC 
Single phase unless otherwise noted.
Note: 
This electrical service require 3 
current carrying conductors (Neutral, 
L1 and L2) and a separate conductor 
for earth ground
Note: 
Power cord must be 
connected to center terminal 
block on all Twins unless 
otherwise noted.
Twins