ROUTINE CLEANING
Rinsing the brew funnel and decanter after each use 
is the only routine cleaning required. Occasionally, wipe 
the outside of the brewer including the area above the 
funnel with a damp cloth. (The brew funnel and decanter 
are top-rack dishwasher safe.)
DELIMING
Periodically, you should delime the brewer to clear any 
deposits that may have accumulated due to impurities in the water source.
NOTE- Unplug the brewer and let it cool down before deliming.
1)  Unscrew the sprayhead with your fingertips and set it aside.
2)  Insert  all  but  two  inches  of  the  flexible  deliming  tool 
(supplied) into the sprayhead tube.
3)  Slide the tool in and out five or six times to loosen lime 
in the sprayhead tube. Remove the tool.
4)  Pour one decanter of fresh water into the brewer, set the 
empty decanter on the warmer, and close the lid.
5)  Check the holes in the sprayhead. If plugged with lime, 
they  may  be  cleared  by  using  a  toothpick.  Clean  the 
sprayhead  with  a  cloth  and  mild  detergent.  Rinse  the 
sprayhead with water before reinstalling.
6)  Plug in the brewer and allow the water in the tank to 
reheat before using. The frequency of deliming depends 
on the mineral content of your water.
(Recommended at least every three months)
1)  Slide an empty brew funnel into the brewer under the warmer switch and 
center an empty decanter on the warmer.
2)  Pour one quart of white vinegar into the top of the brewer and close the lid. 
Empty the decanter when liquid stops flowing from the funnel.
3)  Allow the brewer to sit for two hours.
4)  Unplug the brewer. Remove the brew funnel and sprayhead from the brewer 
and set them aside.  Clean the sprayhead with a cloth and mild detergent. 
5)  To drain the brewer, continue to Step 6, OR to clear vinegar out of brewer 
without  draining,  pour  a  decanter  of  fresh,  cold  water  through  the  brewer.  
Place decanter on warmer, then close the lid to allow the water to run through 
the brewer.  After it has run through, empty decanter, and repeat the process 
approximately 8 - 10 times. Proceed to Step 9.
6)  Cool the brewer by pouring a full decanter of fresh, cold water into the top 
of the brewer. Place decanter on warmer, close lid. When water has stopped 
flowing from the brewer, empty the decanter.  Repeat this process one more 
time, then set the decanter aside.
P227
P228
P2248
BU
NN
ON
OF
F
WA
RM
ER
OFF
O
N
P2248
PERIODIC CLEANING