Bunn cdbcf 15 Guía Del Usuario

Descargar
Página de 48
Page 5
Will not refi ll
Refi ll does not shut off
Power "ON"
Refi ll does not shut off
Power "OFF"
PROBABLE CAUSE
REMEDY
PROBLEM
1. Power off to brewer  
2. Water shut off
3. Error Message
4.ON/OFF Switch
(If equipped)
5. Lime build up on Probe(s)
6. Refi ll Valve or Control Board
1. Lime build up on probe
2. Water Level Sensing System
3. Refi ll valve or control board
1. Refi ll valve
Press OFF/ON switch on control 
panel to determine if power is ON.
Make sure water is ON.
Brewer has shut down due to mal-
function (See Diagnostic Section in 
this manual).
Make sure ON/OFF Switch is "ON" 
and indicator is lit.
Remove the Level Probe(s) and 
check for lime deposit on tip. Clean 
and reinstall.
Refer to page 19
Remove Level Probe and check 
for lime deposits on tip. Clean and 
reinstall.
Replace control board
Check valve. Page 19
Clean or replace valve as needed. 
Page 19
TROUBLESHOOTING (cont.)
REFILL CIRCUIT
39132 080409