Bunn dual sh brewwise dbc Guía De Operación

Descargar
Página de 54
Page 39
SERVICE TOOLS (cont.)
front of the brewer except the upper right hidden 
switch.  While the switch is pressed, the display 
shows the name of that switch.  If the name does 
not appear, or if it remains after the switch has been 
released, the switch is defective.  Each switch can 
be tested in this manner. 
9.  After all switches have been tested, press and re-
lease the right hidden switch (®). This will return 
to TEST SWITCHES?. Press and release switch 
again  to  advance  to  TEST  SERVERS?.  Another 
alternative is to press and release either ON/OFF 
switch  located  on  the  front  switch  panel.  This 
will exit TEST SWITCHES and return to the MAIN 
SCREEN.
Procedures to test servers: 
 
This function allows the operator to test the opera-
tion of the Soft Heat servers. It will also show if the 
server is correctly placed on the brewer stand.
1.  Place  brew  funnels  into  rails  on  both  sides  of 
brewer.
2.  Place a Soft Heat server beneath each brew fun-
nel.
3.  Press and hold the upper right hidden switch until 
the display reads UNITS. Release the switch. Con-
tinue to press and release switch until SERVICE 
TOOLS? appears. 
4.  Pressing NO  will exit this function and advance to 
the next function screen. Press YES to run tests 
on  various  components  and  outputs  within  the 
brewer.
5.  The display should read TEST OUTPUTS?
6.  In TEST OUTPUTS screen, press NO. This advances 
to TEST SWITCHES?. Press and release NO once 
more. The display should now read TEST SERV-
ERS?
7.  Press YES in the TEST SERVERS screen to show 
if a server is in place. The display should read IN 
PLACE with arrows pointing to the left and right
8.  Lift and pull both Soft Heat servers forward about 
2 inches so that the two contacts on each server 
do not touch the two contacts on the brewer.
9.  The display should then read SERVER REMOVED 
with arrows pointing to the left and right.
10. After  the  servers  have  been  tested,  press  and 
release either ON/OFF switch located on the front 
switch panel. This will exit TEST SERVERS  and 
return to the MAIN SCREEN.
Procedures to test coil frequency:
1.  Place  brew  funnels  into  rails  on  both  sides  of 
brewer.
2.  Place a Soft Heat server beneath each brew fun-
nel.
3.  Press and hold the upper right hidden switch un-
til the display reads UNITS. Release the switch. 
Continue pressing and releasing the upper right 
hidden switch until SERVICE TOOLS appears. 
4.  Pressing NO  will exit this function and advance to 
the next function screen. Press YES to run tests 
on  various  components  and  outputs  within  the 
brewer.
5.  The display should read TEST OUTPUTS?.
6.  In TEST OUTPUTS screen, press NO.  Continue to 
press and release NO until the display reads  TEST 
FREQUENCY?.
7.  Press and release YES. The display will show the 
frequency of the sensor coil circuits. This is for 
diagnostic service use when troubleshooting this 
circuit.
8.  After the coils have been tested, press and release 
either ON/OFF switch located on the front switch 
panel. This will exit the TEST FREQUENCY function 
and return to the MAIN SCREEN.
NOTE: If the operator wishes to test more than one 
function in the SERVICE TOOLS section (outputs, 
switches,  servers,  or  coil  frequency),  it  is  not 
necessary to exit the program. Use the flow chart 
for  SERVICE  TOOLS  to  navigate  to  a  particular 
function.