SERVICE TOOLS (cont.)
PROGRAMMING THE BREWER (cont.)
9.  After all switches have been tested, press and re-
lease the right hidden switch (®). This will return 
to TEST SWITCHES?. Press and release switch 
again  to  advance  to  TEST  SERVERS?.  Another 
alternative is to press and release either ON/OFF 
switch  located  on  the  front  switch  panel.  This 
will exit TEST SWITCHES and return to the MAIN 
SCREEN.
Procedures to test coil frequency:
1.  Place  brew  funnels  into  rails  on  both  sides  of 
brewer.
2.  Place a Soft Heat server beneath each brew fun-
nel.
3.  Press  and  hold  the  upper  right  hidden  switch 
until the display reads UNITS. Release the switch. 
Continue pressing and releasing the upper right 
hidden switch until SERVICE TOOLS appears. 
4.  Pressing NO  will exit this function and advance to 
the next function screen. Press YES to run tests 
on  various  components  and  outputs  within  the 
brewer.
5.  The display should read TEST OUTPUTS?.
6.  In TEST OUTPUTS screen, press NO.  Continue to 
press and release NO until the display reads  TEST 
FREQUENCY?.
7.  Press and release YES. The display will show the 
frequency of the sensor coil circuits. This is for 
diagnostic service use when troubleshooting this 
circuit.
8.  After the coils have been tested, press and release 
either ON/OFF switch located on the front switch 
panel. This will exit the TEST FREQUENCY function 
and return to the MAIN SCREEN.
NOTE: If the operator wishes to test more than one 
function in the SERVICE TOOLS section (outputs, 
switches,  servers,  or  coil  frequency),  it  is  not 
necessary to exit the program. Use the flow chart 
for  SERVICE  TOOLS  to  navigate  to  a  particular 
function.
FACTORY DEFAULTS
 
This function allows the operator to erase all of the 
previously entered recipes and ad messages. Factory-
set default values will replace all previous settings.
EXIT
EXIT
REPLACE
WILL REPLACE ALL
BREW SETTINGS
ARE YOU SURE?
NO                     YES
FACTORY DEFAULTS
NO                     YES
ThermoF  SoftHeat
DONE
SEL BREWER TYPE?
NO                     YES
P2312
Procedure to set factory defaults:
1.  Press and hold the upper right hidden switch until 
UNITS  appears.  Release  the  switch.  Press  and 
release  the  upper  right  hidden  switch  until  the 
display reads SEL BREWER TYPE?
2.  Pressing NO in this screen will advance to FACTORY 
DEFAULTS. Press and release YES. The display 
should  read  ThermoF  SoftHeat.  The  selected 
brewer type will be flashing. When correct brewer 
type is selected press DONE.
3.  The display should now read FACTORY DEFAULTS
Pressing NO in this screen will revert to the MAIN 
SCREEN.  Press YES to replace the defaults.  This 
advances to WILL REPLACE ALL BREWING SET-
TINGS.  This screen will alternate with ARE YOU 
SURE?.
4.  Pressing NO in the confirmation screen will revert 
to MAIN SCREEN, without resetting the brewing 
setups to the defaults. Press YES to load the de-
faults. This will then revert to the MAIN SCREEN
and  the  factory  default  values  will  replace  all 
previously entered values. It will NOT reset the 
summation Brew counter.
35058.1 071205