SERVICE (cont.)
FROTHER AND WHIPPER MOTOR
FIG. 15 FROTHER AND WHIPPER MOTOR
P1641.40
Location:
 
The frothers are located behind the dispenser door, 
mounted on the whipper motor shaft inside the whipper 
chamber.
 
The whipper motors are located on the back side 
of the whipper motor mounting panel.
Test Procedure:
1.  Check that the rinse/run switch is in the rinse (up) 
position.
2.  Disconnect the dispenser from the power source.
3.  Disconnect the white/violet and white wires on the 
right motor, orange and white wires on the center 
motor or the red and white wires on the left motor 
from the black leads on the motors.
4.  Press  and  hold  the  appropriate  dispense  switch 
and, with a voltmeter, check the voltage across the 
disconnected harness. Connect the dispenser to the 
power source. The reading must be:
 
a) 120 volts ac for two wire 120 volt models, three 
wire 120/208 volt and 120/240 volt models.
 
b) 240 volts ac for two wire 240 volt models.
 
c) 230 volts ac for two wire 230 volt models.
5.  Disconnect the dispenser from the power source.
If voltage is present as described, replace the motor.
If voltage is not present as described, refer to the Wiring 
Diagrams and check the dispenser wiring harness
                     9       8     7  6    5   4   3
10
FIG. 16 MIXING/WHIPPER CHAMBER 
COMPONENTS
P1630.35
1.   Steam Collector
2.   Mixing Chamber 
3.   Dispense Tip
4.   Whipper Chamber
5.   O-Ring
6.  Frother
7.   Nut
8.  Receptacle w/Seal
9.   Slinger
10.  Motor Assy.
11.  Fan
12.  Vacuum Hose
13.  Baffle
11  12  13
1    2
29170 090407
Removal,  Cleaning  and  Replacement  (Refer  to  Fig. 
16):
1.  Open the dispenser door and raise the top front 
cover.
2.  Lift the front edge of each hopper assembly over 
the tab on the hopper support panel and slide each 
hopper assembly out the front of the dispenser. Set 
aside for reassembly.
3.  Remove the four #8-32 screws securing the hopper 
support panel to auger motor mounting panel and 
the whipper motor mounting panel. Set aside for 
reassembly.
4.  Disconnect  vacuum  hose  (12)  from  fan  baffle 
(13).
5.  Remove the steam collector (1) by pulling it forward 
and at the same  time twisting it clockwise.