Bunn FMD-4 Guía Del Usuario
11
TROUBLESHOOTING (cont.)
PROBLEM
Product overflows container
Weak product
PROBABLE CAUSE
1. Dispense Switch
2. Dispense Solenoid Valve
1. Water Temperature
2. Whipper Motor
3. Frother
4. Dispense Solenoid Valve
5. Auger Drive
6. Auger Spring
7. Auger Motor
8. Rinse/Run Switch
9. Rinse Timer
10. Relay (120V versions only)
11. Control Board #2 (120V versions
only)
REMEDY
Refer to Service - Dispense Switch for
testing procedures. See page 23
Remove the solenoid valve and clear
any obstructions. Rebuild or replace
the valve if necessary. See page 35
Place an empty container beneath
the dispense tip. Initiate a dispense
cycle and check the water temperature
immediately below the dispense tip
with a thermometer. Reading should
be 180°F to 200°F (see thermostat
temperature settings decal in USER
NOTICES on page 3.)
Refer to Service - Whipper Motor for
testing procedure. See page 27
Refer to Service - Frother Compo-
nents. See page 26
Refer to Service - Dispense Solenoid
Valve for test procedures. See page
35
Refer to Service - Auger Drive Com-
ponents. See page 13 & 15
Refer to Service - Auger Drive Com-
ponents. See page 13 & 15
Refer to Service - Auger Drive Com-
ponents. See page 13 & 15
Refer to Service - Rinse/Run Switch
for test procedures. See page 32
Refer to Operation - Rinse Timer.
See Page 5
Refer to Service - Relay for testing
procedures. See page 40
Refer to Service - Control Board #2
for testing procedures. See page 22
35135 012103