Bunn FMD-4 Guía Del Usuario

Descargar
Página de 46
11
TROUBLESHOOTING (cont.)
PROBLEM
Product overflows container
Weak product
PROBABLE CAUSE
1. Dispense Switch
2. Dispense Solenoid Valve
1. Water Temperature
2. Whipper Motor
3. Frother
4. Dispense Solenoid Valve
5. Auger Drive
6. Auger Spring
7. Auger Motor
8. Rinse/Run Switch
9. Rinse Timer
10. Relay (120V versions only)
11. Control Board #2 (120V versions 
only)
REMEDY
Refer to Service -  Dispense Switch for 
testing procedures. See page 23
Remove the solenoid valve and clear 
any obstructions. Rebuild or replace 
the valve if necessary. See page 35 
Place  an  empty  container  beneath 
the dispense tip. Initiate a dispense 
cycle and check the water temperature 
immediately below the dispense tip 
with a  thermometer. Reading should 
be 180°F to 200°F (see thermostat
temperature settings decal in USER 
NOTICES on page 3.)
Refer to Service - Whipper Motor for 
testing  procedure. See page 27
Refer  to  Service  -  Frother  Compo-
nents. See page 26
Refer to Service - Dispense Solenoid 
Valve for test procedures. See page 
35
Refer to Service - Auger Drive Com-
ponents. See page 13 & 15
Refer to Service - Auger Drive Com-
ponents. See page 13 & 15
Refer to Service - Auger Drive Com-
ponents. See page 13 & 15
Refer to Service - Rinse/Run Switch 
for test procedures. See page 32
Refer  to  Operation  -  Rinse  Timer. 
See Page 5
Refer to Service  - Relay for testing 
procedures. See page 40
Refer to Service  - Control Board #2 
for testing procedures. See page 22
35135 012103