Bunn ICB Guía Del Usuario

Descargar
Página de 70
Page 39
PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL  2 (cont.)
ENABLE FRESH TIMER
This function allows the operator to enable the Freshness 
Alert and set the expiration time.  The expiration time is 
the amount of time the product is allowed to sit in the 
server/dispenser before a fresh batch is brewed.
Procedure for enabling/setting the Freshness Timer
Range:  Coffee 0.5 to 4.0 hrs
 
  Hot Tea 0.5 to 8.0 hrs
If enabled, default setting is 2.0 hrs. for Coffee and 2.0 
hrs. for Hot Tea.
1.  Press and hold the right hidden button until the 
display reads SET LANGUAGE. Press the right 
hidden button until the display reads ENABLE 
FRESHTIMER
.
2.  Press and release the NO button to disable this 
function, or:
3.  Press and release the YES  button to enable this 
function (the unit will display a message once the 
set time has expired).
4.  When fi nished, press and release DONE to save 
the new setting and advance to the next function 
screen.  
5. If NO was selected, the display should now read 
REFILL. To exit programming and return to the MAIN 
SCREEN
, press and release the ON/OFF pad.
6. If YES was selected, the display should now read 
COFFEE.  This screen allows the operator to set the 
amount of time from the end of brewing a batch 
of coffee until a Freshness Alert message will be 
displayed.  Using (-) and (+), adjust the freshness 
time for coffee .  When fi nished, press and release 
DONE.
7.  The display should now read HOT TEA. Using (-) 
and (+), adjust the freshness time for hot tea.  When 
fi nished, press and release DONE.
8.  This display should now read REFILL. To exit pro-
gramming and return to the MAIN SCREEN, press 
and release the ON/OFF pad.
P3092
BREW
A
BREW
B
BREW
C
WITH NO FLASHING
PRESS DONE.
PRESSING DONE WILL
ADVANCE TO
REFILL.
WHEN TIME HAS EXPIRED,
THE DISPLAY WILL READ:
ENABLEFRESHTIMER
NO     DONE    YES
FRESHNESS ALERT
BREW X
FRESHNESS ALERT
BREW FRESH BATCH
READY TO BREW
WATER TEMP: 200°
BREW
A
BREW
B
BREW
C
COFFEE
(-)    DONE    (+)
BREW
A
BREW
B
BREW
C
HOT TEA
(-)    DONE    (+)
XXX    REFILL    155
(-)    DONE    (+)
WITH YES FLASHING
PRESS DONE
9.  Once the set time has expired, the display will read 
FRESHNESS ALERT BREW (A,B or C), and then 
FRESHNESS ALERT BREW FRESH BATCH 
alternat-
ing with the MAIN SCREEN.  
10.  Empty the server/dispenser the previous batch was 
brewed into and replace under the funnel.
11. Brew a new batch  
12. The freshness timer will reset.  The display should 
now return to the MAIN SCREEN.