PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL  2 (cont.)
CALIBRATE FLOW (Continued)
Procedure to calibrate the bypass fl ow rate:
1.  Place a container, accurately graduated and with a 
minimum capacity of 60 ounces, beneath the fun-
nel.
NOTE: If the display is already on the BYPASS CAL 
screen, skip steps 2 & 3 and proceed directly to step 
4. 
2.  Press and hold the right hidden button until the 
display reads SET LANGUAGE. Press the right 
hidden button until the display reads CALIBRATE 
FLOW
.  
3. Press and release YES to advance to the SPRAY 
HEAD CAL function screen. Press and release NO 
to advance to BYPASS CAL.
4.  Press and release the YES pad. The display should 
read CONTAINER READY?  If the container is under 
the funnel, press YES.  
5.  The display should read CALIBRATE BYPASS. Press 
and release START to begin the fl ow for calibration. 
The display should read CALIBRATE BYPASS...60 
SEC TO FINISH.
 The 60-second timer on the display 
will count down to zero. When the counter reaches 
zero, the display will changes to BYPASS OZ/M
along with a number.
6.  Measure the amount of water in the container and 
using the (-) and (+) pads, adjust the amount of 
the display to match the amount in the container. 
Then press DONE.
7.  The display should now read NEW BYPASS FLOW
along with the correct fl ow rate of the bypass.  
After about 5 seconds, the display will return to 
CALIBRATE FLOW SCREEN. To exit programming, 
press and release the ON/OFF button to return to 
the MAIN SCREEN.
P3096
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
CALIBRATE FLOW?
NO               YES
SPRAY HEAD CAL
NO               YES
CALIBRATE FLOW?
NO               YES
CONTAINER READY?
QUIT              YES
BYPASS CAL?
NO               YES
CALIBRATE BYPASS
60 SEC TO FINISH
BYPASS OZ  XX.X
(-)    DONE    (+)
NEW BYPASS FLOW
XX.X  OZ/M 
PRESSING NO WILL
ADVANCE TO
BREW COUNTERS
5 SEC.
CALIBRATE BYPASS
QUIT            START