Page 44
PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
CALIBRATE FLOW (Continued)
Procedure to calibrate the bypass fl ow rate:
1. Place a container, accurately graduated and with a
1. Place a container, accurately graduated and with a
minimum capacity of 60 ounces, beneath the fun-
nel.
nel.
NOTE: If the display is already on the BYPASS CAL
screen, skip steps 2 & 3 and proceed directly to step
4.
screen, skip steps 2 & 3 and proceed directly to step
4.
2. Press and hold the right hidden button until the
display reads SET LANGUAGE. Press the right
hidden button until the display reads CALIBRATE
FLOW.
hidden button until the display reads CALIBRATE
FLOW.
3. Press and release YES to advance to the SPRAY
HEAD CAL function screen. Press and release NO
to advance to BYPASS CAL.
to advance to BYPASS CAL.
4. Press and release the YES pad. The display should
read CONTAINER READY? If the container is under
the funnel, press YES.
the funnel, press YES.
5. The display should read CALIBRATE BYPASS. Press
and release START to begin the fl ow for calibration.
The display should read CALIBRATE BYPASS...60
SEC TO FINISH. The 60-second timer on the display
will count down to zero. When the counter reaches
zero, the display will changes to BYPASS OZ/M,
along with a number.
The display should read CALIBRATE BYPASS...60
SEC TO FINISH. The 60-second timer on the display
will count down to zero. When the counter reaches
zero, the display will changes to BYPASS OZ/M,
along with a number.
6. Measure the amount of water in the container and
using the (-) and (+) pads, adjust the amount of
the display to match the amount in the container.
Then press DONE.
the display to match the amount in the container.
Then press DONE.
7. The display should now read NEW BYPASS FLOW,
along with the correct fl ow rate of the bypass.
After about 5 seconds, the display will return to
CALIBRATE FLOW SCREEN. To exit programming,
press and release the ON/OFF button to return to
the MAIN SCREEN.
After about 5 seconds, the display will return to
CALIBRATE FLOW SCREEN. To exit programming,
press and release the ON/OFF button to return to
the MAIN SCREEN.
P3096
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
CALIBRATE FLOW?
NO YES
SPRAY HEAD CAL
NO YES
CALIBRATE FLOW?
NO YES
CONTAINER READY?
QUIT YES
BYPASS CAL?
NO YES
CALIBRATE BYPASS
60 SEC TO FINISH
BYPASS OZ XX.X
(-) DONE (+)
NEW BYPASS FLOW
XX.X OZ/M
PRESSING NO WILL
ADVANCE TO
BREW COUNTERS
5 SEC.
CALIBRATE BYPASS
QUIT START
37077 101205