Bunn ICB Guía Del Usuario

Descargar
Página de 70
Page 56
PROBABLE CAUSE
REMEDY
PROBLEM
TROUBLESHOOTING (cont.)
Temperature Too Low
Heating Time Too Long
Fill Time Too Long
Temp Sensor Out Of Range, Check 
For Bad Connections
Temp Sensor Out Of Range, Check 
Wire For Shorts
Equipment will not operate
1. Water temperature in the tank 
does not meet the ready tempera-
ture.
1. Tank Heater failure.
2. Control Board/Thermistor fail-
ure
1. Water shut off to brewer
2. Tank Drain clamp is shut
3. Inlet Solenoid failure
4. Control Board Failure
5. ON/OFF switch is OFF
1. Temperature Sensor Probe 
wire(s) broken or not making con-
nection
1. Temperature Sensor Probe 
wire(s) shorted to housing or to 
each other.
1. No power or incorrect voltage
A)  Wait for the brewer to heat to 
the proper temperature.
B) Disable the BREW LOCKOUT 
function.  See page 17 for proce-
dure.
Service required
Service required
Check water supply shut-off
Check tank drain clamp
Service Required
Service Required
Turn switch ON
Check wire and connection of both 
black and white wires of temperature 
probe.
Check to confi rm that wire(s) are 
not pinched between two surfaces 
or connected to each other.
Measure the voltage at the terminal 
block and confi rm that it matches 
the voltage specifi ed on the brewer 
data plate withing +/- 10%.
37077 091704