Solenoid Valve
Location:
The  solenoid  valve  is  located  within  the  side  of  the 
dispenser on the right side near the bottom.
To test the solenoid valve, access will also be needed 
to the electronic control assembly.
HAZ
ARDOU
S
VOLT
AGE
DISCO
NNEC
T FRO
M
POW
ER SO
URCE
BEFO
RE RE
MOVIN
G!
WAR
NING
P1994
FIG. 9 SOLENOID VALVE
SERVICE (cont.)
Test Procedure:
1.  Disconnect the dispenser from the power source 
and turn off the water supply to the dispenser.
2.  Remove the pink wire from terminal 5 of the elec-
tronic control assembly.
3.  Check the voltage across the solenoid valve coil 
terminals with a voltmeter. Connect the dispenser 
to the power source. The indication must be 200 
to 240 volts ac for 200 to 240 volt models after a 
delay of approximately 5 seconds.
4.  Disconnect the dispenser from the power source.
If voltage was present as described, proceed to #5.
If voltage was not present as described, refer to the 
Wiring Diagrams and check the dispenser wiring har-
ness.
5.  Remove both wires from the solenoid valve coil 
terminals.
6.  Check for continuity across the solenoid valve coil 
terminals.
If  continuity  is  present  as  described,  reconnect  the 
wires and proceed to #7.
If continuity is not present as described, replace the 
solenoid valve coil.
7.  Check the solenoid valve for coil action. Connect 
the dispenser to the power source. Listen carefully 
in the vicinity of the solenoid valve for a “clicking” 
sound after approximately 5 seconds, as the coil 
magnet attracts the plunger.
8.  Disconnect the dispenser from the power source.
9.  Reconnect the pink wire to terminal 5 of the elec-
tronic control assembly.
If the sound was heard as described and water will 
not pass through the solenoid valve, there may be a 
blockage in the water line before or after the solenoid 
valve or the solenoid valve may require inspection for 
wear and removal of waterborne particles.
If the sound was not heard as described, replace the 
solenoid valve.
Removal and Replacement:
1.  Remove all wires from the solenoid valve coil.
2.  Turn off the water supply to the dispenser.
3.  Disconnect the water lines to and from the solenoid 
valve.
4.  Remove the two 8-32 slotted-head screws holding 
the  solenoid  valve  and  mounting  bracket  to  the 
component bracket.