Bunn H5E Guía Del Usuario

Descargar
Página de 22
16
SERVICE (cont.)
Limit Thermostat
Location:
The limit thermostat is located on the tank lid.
To test the limit thermostat, access will also be needed 
to  the  terminal  block  located  at  the  rear  of  the  dis-
If voltage was present as described, reconnect the black 
wire and proceed to #5.
If voltage was not present as described, refer to the 
Wiring Diagrams and check the dispenser wiring har-
ness.
5.  Check for continuity across the terminals of  the 
limit thermostat.
If continuity is not present as described, the circuit is 
broken. Press the reset button of the limit thermostat 
and recheck for continuity.
If continuity is not present as described, replace the 
limit thermostat.
Removal and Replacement:
1.  Remove both wires from the limit thermostat ter-
minals.
2.  Remove the two #10-32 nuts attaching the limit 
thermostat to the top of the tank.
3.  Install  the  new  limit  thermostat  and  secure  into 
place with two #10-32 nuts.
4.  Refer to FIG. 7 when reconnecting the wires.
penser.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  There are two black wires on the limit thermostat 
terminals. One comes from the terminal block. The 
other goes directly to the tank heater terminal.  Re-
move the black wire at the limit thermostat coming 
from the terminal block.
3.  Check the voltage across the black wire removed 
from the limit thermostat and the white wire or red 
wire of the terminal block with a voltmeter. Connect 
the dispenser to the power source. The indication 
must be:
 
a.) 100 to 120 volts ac for 100 to 120 volt models 
or
 
b.) 200 to 240 volts ac for 200 to 240 volt models
 
or
 
c.) 230 volts ac for 230 volt models.
4.  Disconnect the dispenser from the power source.
FIG. 6 LIMIT THERMOSTAT
FIG. 7 LIMIT THERMOSTAT WIRING
BLK to Terminal Block
BLK to Tank Heater
P1772
P1776
Reset
10420 091902