5
PLUMBING REQUIREMENTS
This dispenser must be connected to a cold water system with operating pressure between 20 and 90 psi from a 
1⁄2” or larger supply line.  A shut-off valve should be installed in the line before the dispenser.  Install a regulator 
in the line when pressure is greater than 90 psi to reduce it to 50 psi.  The water inlet fitting is 1⁄4” flare.
NOTE - Bunn-O-Matic recommends 1⁄4” copper tubing for installations of less than 25 feet and 3⁄8” for more 
than 25 feet from the 1⁄2” water supply line.  At least 18 inches of an FDA approved flexible beverage tubing, 
such as reinforced braided polyethylene or silicone, before the dispenser will facilitate movement to clean the 
countertop.  Bunn-O-Matic does not recommend the use of a saddle valve to install the dispenser.  The size and 
shape of the hole made in the supply line by this type of device may restrict water flow.
This equipment must be installed to comply with the Basic Plumbing Code of the Building 
Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation 
Manual of the Food and Drug Administration (FDA). For models installed outside the U.S.A., 
you must comply with the applicable Plumbing/Sanitation codes for your area.
NOTE - If a backflow preventer is required by code, a shock arrestor should be installed between backflow pre-
venter and dispenser. Installing the shock arrestor as close to the dispenser as possible will provide the best 
results.
PLUMBING HOOK-UP
1.  Flush the water line and securely attach it to the elbow fitting on the bottom of the dispenser.
2.  Turn on the water supply.
37510 090407