PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL  2 (cont.)
CALIBRATE FLOW (Continued)
Procedure to calibrate the dilution flow rate:
1.  Place a container, accurately graduated and with 
a minimum capacity of 130 ounces, beneath the 
funnel.
NOTE: If the display is already on the DILUTION CAL 
screen, skip steps 2 & 3 and proceed directly to step 
4. 
2.  Press and hold the right hidden button until the 
display  reads  SET  LANGUAGE.  Press  the  right 
hidden button until the display reads CALIBRATE 
FLOW.  
3.  Press and release YES to advance to the SPRAY 
HEAD CAL function screen. Press and release NO 
to advance to DILUTION CAL.
4.  Press and release the YES pad. The display should 
read CONTAINER READY?  If the container is under 
the funnel, press YES.  
5.  The display should read CALIBRATE DILUTE. Press 
and release START to begin the dilution flow for 
calibration.  The  display  should  read  CALIBRATE 
DILUTE...60 SEC TO FINISH. The 60-second timer 
on the display will count down to zero. When the 
counter reaches zero, the display will changes to 
DILUTE OZ/M, along with a number.
6.  Measure the amount of water in the container and 
using the (-) and (+) pads, adjust the amount of 
the display to match the amount in the container. 
Then press DONE.
7.  The display should now read 
NEW DILUTE FLOW
along with the correct flow rate of the sprayhead.  
After about 5 seconds, the display will return to the 
CALIBRATE FLOW screen, BREW COUNTERS. To 
exit programming, press and release the ON/OFF 
button to return to the MAIN SCREEN.
P2880
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
CALIBRATE FLOW?
NO               YES
SPRAY HEAD CAL
NO               YES
CALIBRATE FLOW?
NO               YES
CONTAINER READY?
QUIT              YES
DILUTION CAL?
NO               YES
CALIBRATE DILUTE
60 SEC TO FINISH
DILUTE  OZ  XX.X
(-)    DONE    (+)
NEW DILUTE FLOW
XX.X  OZ/M 
PRESSING NO WILL
ADVANCE TO
BREW COUNTERS
5 SEC.
CALIBRATE DILUTE
QUIT            START
36748 101505