Bunn LCA-2 IC Guía De Operación

Descargar
Página de 26
22
Screen Displayed 
 
Possible Cause 
 
 
 
Troubleshooting Procedures
Dispenser Diagnostics-LCD Display
Troubleshooting (Continued)
LF TARGET RPM
TOO HIGH !!
TUBE TOO SMALL
CHECK DISP RATIO
RT TARGET RPM
TOO HIGH !!
TUBE TOO SMALL
CHECK DISP RATIO
LF TARGET RPM
TOO LOW !!
TUBE TOO LARGE
CHECK DISP RATIO
RT TARGET RPM
TOO LOW !!
TUBE TOO LARGE
CHECK DISP RATIO
LEFT BIB EMPTY!
REPLACE PRODUCT
CHECK THRESHOLD
RIGHT BIB EMPTY!
REPLACE PRODUCT
CHECK THRESHOLD
1.  The  Tube  Size  selected  for  the  Left 
Hand Dispenser is too small for the 
application.
2.  The Ratio selected for the Left Hand 
Dispenser  is  not  correct  for  the 
application.
1.  The Tube Size selected for the Right 
Hand Dispenser is too small for the 
application.
2.  The  Ratio  selected  for  the  Right 
Hand Dispenser is not correct for the 
application.
1.  The  Tube  Size  selected  for  the  Left 
Hand Dispenser is too large for the 
application.
2.  The Ratio selected for the Left Hand 
Dispenser  is  not  correct  for  the 
application.
1.  The Tube Size selected for the Right 
Hand Dispenser is too large for the 
application.
2.  The  Ratio  selected  for  the  Right 
Hand Dispenser is not correct for the 
application.
1.  Concentrate BIB is Empty.
2.  BIB Not properly connected.
3.  Tubing kinked or blocked.
4.  Empty BIB Warning set too high.
1.  Concentrate BIB is Empty.
2.  BIB Not properly connected.
3.  Tubing kinked or blocked.
4.  Empty BIB Warning set too high.
Refer to “Selecting the Correct Pump 
Tubing” section of the manual.
Refer to recommended Dispense Ratio 
on the product label.
Refer to “Selecting the Correct Pump 
Tubing” section of the manual.
Refer to recommended Dispense Ratio 
on the product label.
Refer to “Selecting the Correct Pump 
Tubing” section of the manual.
Refer to recommended Dispense Ratio 
on the product label.
Refer to “Selecting the Correct Pump 
Tubing” section of the manual.
Refer to recommended Dispense Ratio 
on the product label.
Replace BIB, see loading the Concentrate
Check BIB Connector Fittings
Check Tubing installation
Check Threshold, see Field Calibrating 
the Empty BIB Warning
Replace BIB, see loading the Concentrate
Check BIB Connector Fittings
Check Tubing installation
Check Threshold, see Field Calibrating 
the Empty BIB Warning